[PACKAGE]: ../../raw/master/mkp/dell_powerconnect_psu-0.0.4-20230330.mkp "dell_powerconnect_psu-0.0.4-20230330.mkp"
[PACKAGE]: ../../raw/master/mkp/dell_powerconnect_psu-0.0.5-20240616.mkp "dell_powerconnect_psu-0.0.5-20240616.mkp"
# Dell Power connect PSU
Monitors the status of Dell Power connect power supplys.
......
File added
......@@ -11,6 +11,7 @@
# 2023-03-30: Rewritten for cmk 2.x
# added current power consumption metric
# 2024-06-16: fix crash in parse function ValueError (not enough values to unpack (expected 5, got 4))
# Tested with Dell PowerConnect 5448 and 5424 models.
# Relevant SNMP OIDs:
......@@ -107,7 +108,11 @@ def parse_dell_powerconnect_psu(string_table: List[StringTable]) -> Optional[Dic
return
section = {}
for device_id, name, state, supply, current_power in string_table[1]:
for entry in string_table[1]:
try:
device_id, name, state, supply, current_power = entry
except ValueError:
continue
# M6220 are blade switches which report valid values only for the "Main"
# sensor. The other one is reported as notFunctioning, but this is wrong.
# Simply ignore the "System" sensor for those devices.
......
......@@ -10,7 +10,7 @@
'gui': ['metrics/psu_wattage.py']},
'name': 'dell_powerconnect_psu',
'title': 'Dell Power connect PSU',
'version': '0.0.4-20230330',
'version': '0.0.5-20240616',
'version.min_required': '2.1.0b1',
'version.packaged': '2.2.0p24',
'version.packaged': 'cmk-mkp-tool 0.2.0',
'version.usable_until': None}