This plugin will monitor opengear console servers power supplys. It will show the power supply name (if not none) and the device name.
It will also show the input voltage, the output current and the output power.
* [opengear_power_supply.mkp](https://thl-cmk.hopto.org/gitlab/checkmk/opengear/opengear_power_supply/-/raw/master/opengear_power_supply.mkp "Download the MKP file")
You can install the package by uploading it to your CheckMK site and as site user run `mkp install opengear_power_supply.mkp`.
In the Enterprise/Free edition of CheckMK you can use the GUI to install the package (_Setup_ -> _Extension Packages_ -> _Upload package_)
---
### Want to Contribute?
Nice ;-) Have a look at the [contribution guidelines](CONTRIBUTING.md "Contributing")
---
### Check Info
The plugin creates the service **_Power supply_** for each power supply with the **_power supply index_** as item.
| State | condition | WATO |
| ----- | --------- | ---- |
| WARN/CRIT | at Input voltage upper levels | yes |
| WARN/CRIT | below Input voltage lower levels | yes |
| WARN/CRIT | at Output power upper levels | yes |
</details>
<details><summary>Perfdata</summary>
| Metric | Unit | Perfometer |
| ------ | ------ | ------ |
| Input voltage | Y | yes |
| Output current | A | no |
| Output power | W | no |
</details>
---
### WATO
<details><summary>Service monitoring rule</summary>
| Section | Rule name |
| ------ | ------ |
| Temperature, Humidity, Electrical Parameters, etc. | opengear power supply |
| Input voltage upper levels | 12.7V / 12.9V |
| Input voltage lower levels | 11.3V / 11.1V |
| Output current upper levels | none |
| Output current lower levels | none |
| Output power upper levels | 15.1W / 16.0W |
| Output power lower levels | none |
These defaults are based on the opengear CM81XX data sheet